Command Line Interface Guide
omconfig: Managing Components Using the Instrumentation Service 147
Valid Parameters for Voltage Warning Thresholds
Table 4-16 shows the valid parameters for setting voltage warning
threshold values.
NOTE: Threshold values that you can set vary from one system configuration
to another.
Default Minimum and Maximum Warning Threshold Values
To set both the upper and lower voltage warning threshold values to the
recommended default value, type:
omconfig chassis volts index=2 warnthresh=default
or
omconfig mainsystem volts index=2 warnthresh=
default
You cannot default one value and set another. In other words, if you default the
minimum warning threshold value, you are also selecting the default value for
the maximum warning threshold value.
NOTE: Systems that contain ESM3 capabilities do not allow you to set warning
threshold values to default values.
Specify a Value for Minimum and Maximum Warning Thresholds
To specify values for the voltage probe warning thresholds, you must specify
the number of the probe you are configuring and the minimum and/or
maximum warning threshold values.
Table 4-16. omconfig chassis volts or omconfig mainsystem volts
name=value pair Description
index=<n> Probe index (specify.)
warnthresh=default Sets minimum and maximum warning threshold values
to default.
minwarnthresh=<n> Sets minimum warning threshold value (three decimal
places.)
maxwarnthresh=<n> Sets maximum warning threshold value (three decimal
places.)