Command Line Interface Guide

138 omconfig: Managing Components Using the Instrumentation Service
config=serial
(continued)
mode=directbasic |
directterminal |
directbasicterminal |
modembasic |
modemterminal |
modembasicterminal
directbasic: Type of messaging used for
IPMI messaging over a serial connection.
directterminal: Type of messaging that
uses printable ASCII characters and
allows a limited number of text
commands over a serial connection.
directbasicterminal: Both basic and
terminal mode messaging over a
serial connection.
modembasic: Type of messaging used for
IPMI messaging over a modem.
modemterminal: Type of messaging that
uses printable ASCII characters and
allows a limited number of text
commands over a modem.
modembasicterminal: Both basic and
terminal messaging over a modem.
NOTE: All commands are not supported
on the system.
privilegelevel=
administrator | operator |
user
administrator: Sets the maximum
privilege level that are accepted on a
serial connection, to Administrator.
operator: Sets the maximum privilege
level that are accepted on a serial
connection, to Operator.
user: Sets the maximum privilege level
that are accepted on a serial connection,
to User.
Table 4-12. omconfig chassis remoteaccess or omconfig mainsystem
remoteaccess
(continued)
name=value pair 1
config=
name=value pair 2 Description