Command Line Interface Guide
omconfig: Managing Components Using the Instrumentation Service 131
omconfig chassis remoteaccess or omconfig mainsystem remoteaccess
Use the omconfig chassis remoteaccess or omconfig mainsystem
remoteaccess command to configure:
• Remote access on a local area network (LAN.)
• The serial port for BMC or RAC, whichever is installed.
• The BMC or RAC on a serial over LAN connection.
• Terminal settings for the serial port.
• Advanced settings for a serial over LAN connection.
• Information on a BMC or RAC user.
• Information on IPv6 and IPv4 interfaces.
NOTE: Enter the user ID to configure user information.
Ty p e :
omconfig chassis remoteaccess
or
omconfig mainsystem remoteaccess
The output of the omconfig chassis remoteaccess or omconfig mainsystem
remoteaccess command lists each of the available configurations. Table 4-12
shows the valid parameters:
Table 4-12. omconfig chassis remoteaccess or omconfig mainsystem
remoteaccess
name=value pair 1
config=
name=value pair 2 Description
config=
additional
ipv4=enable | disable enable: IPv4 stack to load on iDRAC.
disable: IPv4 stack to flush on iDRAC.