Command Line Interface Guide
122 omconfig: Managing Components Using the Instrumentation Service
• No information
• Custom information
• Default system information
• Service tag, system name
• Remote access MAC addresses
• System power
• Remote access IP address
• Ambient temperature of the system
• Remote access IPv4 address
• Remote access IPv6 address
•Specify and configure the LCD line number
• View the encryption state report of the LCD
• Configure LCD to indicate an active remote session when the
K
ernel-
based
V
irtual
M
achine (KVM) is available
NOTE: You can configure the Power and NMI buttons only if they are present on
the system.
Table 4-6 shows the valid parameters for the command.
Table 4-6. omconfig chassis frontpanel or omconfig mainsystem frontpanel
name=value pair 1 name=value pair 2 Description
lcdindex=
<index>
NA Specifies the LCD line number.
config=none |
default | custom
NA none: Sets the LCD text to none.
default: Sets the LCD text to default.
custom: Sets the LCD text to custom.
text=<custom
text>
NA Sets the custom text for LCD when config=
custom.
nmibutton=
enable | disable
NA enable: Enables the NMI button on the
system.
disable: Disables the NMI button on the
system.