Command Line Interface Guide

omconfig: Managing Components Using the Instrumentation Service 121
omconfig chassis fans index=0 warnthresh=default
or
omconfig mainsystem fans index=0 warnthresh=
default
You cannot default one value and set another. In other words, if you default
the minimum warning threshold value, you are also selecting the default
value for the maximum warning threshold value.
Specifying a Value for Minimum and Maximum Warning Thresholds
If you prefer to specify values for the fan probe warning thresholds, you must
specify the number of the probe you are configuring and the minimum and/or
maximum warning threshold values. In the following example, the probe that
is being configured is probe 0. The first command sets only the minimum
threshold; the second sets minimum and maximum thresholds:
omconfig chassis fans index=0 minwarnthresh=4580
or
omconfig mainsystem fans index=0 minwarnthresh=
4580
omconfig chassis fans index=0 minwarnthresh=4580
maxwarnthresh=9160
or
omconfig mainsystem fans index=0 minwarnthresh=
4580 maxwarnthresh=9160
When you issue the command and the system sets the values you specify, the
following message is displayed:
Fan probe warning threshold(s) set successfully.
NOTE: You cannot set the minimum and maximum warning thresholds for the fan
probe on PowerEdge x8xx and x9xx systems.
omconfig chassis frontpanel or omconfig mainsystem frontpanel
Use the omconfig chassis frontpanel or omconfig mainsystem frontpanel
command to:
configure the power button and the Nonmasking Interrupt (NMI) button
configure the LCD to display: