User's Manual

Temperature Probe Properties and Tasks
Does my enclosure support this feature? See Supported Features.
Use this window to view information about the enclosure's temperature probes.
Temperature Probe Properties and Tasks
Table 9-6.TemperatureProbeProperties
Set Temperature Probe Properties and Tasks
Click the Set Temperature Probe button to launch the wizard for changing the temperature probe's Warning threshold. You can change the Warning
threshold for each of the temperature probes included in the enclosure. For more information, see Set Temperature Probe Values.
To launch the Set Temperature Probe wizard:
1. Expand the Storage tree object to display the controller objects.
Degraded—The power supply has encountered a failure and is operating in a degraded state.
Failed—The power supply has encountered a failure and is no longer functioning. Storage Management may also be unable to communicate with
the enclosure using SES commands. The Failed state is displayed when the enclosure does not respond to a status query from Storage
Management for any reason. For example, disconnecting the cable would cause this state to be displayed.
Missing—The power supply is not present in the enclosure.
Part
Number
This property displays the part number of the power supply.
This property is not displayed for the PowerVault 22xS enclosures that have E.17 firmware or later.
Property
Definition
Status
These icons represent the severity or health of the storage component. For more information, see Storage Component Severity.
NOTE: On some enclosures, Storage Management may experience a short delay before displaying the current enclosure temperature and
temperature probe status. For more information, see Storage Management May Delay Before Updating Temperature Probe Status.
Name
This property displays the name of the temperature probe.
State
This property displays the current status of the temperature probe.
Ready—The temperature probe is functioning normally.
Degraded—The temperature probe has encountered a failure and is operating in a degraded state.
Failed—The temperature probe has encountered a failure and is no longer functioning. Storage Management may also be unable to
communicate with the enclosure using SES commands. The Failed state is displayed when the enclosure does not respond to a status query
from Storage Management for any reason. For example, disconnecting the cable would cause this state to be displayed.
Minimum Warning Threshold Exceeded—The enclosure's temperature has dropped below the minimum warning threshold. For more
information, see Set Temperature Probe Values.
Maximum Warning Threshold Exceeded—The enclosure's temperature has risen above the maximum warning threshold. For more
information, see Set Temperature Probe Values.
Missing—The temperature probe is not present in the enclosure.
Inactive—The temperature probe is present in the enclosure, but the EMM that it monitors is not installed.
Reading
This property displays the current temperature of the enclosure as reported by the temperature probe.
Warning
Threshold
The Minimum and Maximum properties indicate the temperatures currently set for the Warning threshold. For more information, see Set
Temperature Probe Values.
Failure
Threshold
The Minimum and Maximum properties indicate the temperatures currently set for the Failure threshold. For more information, see Set
Temperature Probe Values.