User's Manual

3. Click Apply Changes. To exit and cancel your changes, click Go Back To Enclosure Information Page.
To locate this task in Storage Management:
1. Expand the Storage tree object to display the controller objects.
2. Expand a controller object.
3. Expand a Connector object.
4. Select the enclosure object.
5. Select the Information/Configuration subtab.
6. Select Set Asset Data from the Available Tasks drop-down menu.
7. Click Execute.
Set Temperature Probe Values
Does my enclosure support this feature? See Supported Features.
The temperature probes monitor the enclosure's temperature. Each temperature probe has a Warning and a Failure threshold. The Warning threshold
indicates that the enclosure is approaching an unacceptably warm or cool temperature. You can modify the Warning threshold.
The Failure threshold indicates that the enclosure has reached a dangerous temperature that may cause damage and data loss. You cannot change the
default values for the Failure threshold.
To change the temperature probe's Warning threshold:
1. The enclosure's temperature probes are listed in the Temperature Probes section of the screen. Select the probes that you want to change.
2. Select Set new values in the Set New Temperature Probe Values section of the screen.
3. Type the lowest acceptable temperature in Celsius for the enclosure in the Minimum Warning Threshold text box. The text box label indicates the
range that you can specify.
4. Type the highest acceptable temperature in Celsius for the enclosure in the Maximum Warning Threshold text box. The text box label indicates the
range that you can specify.
5. Click Apply Changes.
If you want to return the temperature probe's Warning threshold to the default values, select the Reset to default values button and click Apply Changes.
The default values are displayed in the Minimum Warning Threshold and Maximum Warning Threshold text boxes.
To locate this task in Storage Management:
1. Expand the Storage tree object to display the controller objects.
2. Expand a controller object.
3. Expand a Connector object.
4. Select the enclosure object.
5. Select the Information/Configuration subtab.
6. Select Set Temperature Probe Values from the Available Tasks drop- down menu.
7. Click Execute.
NOTE: On some enclosures, Storage Management may experience a short delay before displaying the current enclosure temperature and temperature
probe status. For more information, see Storage Management May Delay Before Updating Temperature Probe Status.