Read me
another name is assigned to these virtual disks and the "IR Virtual
Disk" name is not displayed on the "Preview" page.
* Storage Management supports assignment of only one
dedicated hot spare for a virtual disk on SCSI Controllers.
* Storage Management does not permit connecting the first enclosure
in single path and attaching the subsequent enclosures in
multipath. All enclosures must be connected in multipath to enable
the multipath view.
* An error message may not display when "Import Foreign
Configuration" task is not successful.
Problem: The "Import Foreign Configuration" task can only import
virtual disks that have consistent data. A virtual disk with
inconsistent data cannot be imported. When importing multiple
virtual disks in a single operation, however, the "Import Foreign
Configuration" task may report successful completion even when
inconsistent virtual disks are present and have not been imported
successfully.
Solution: If the "Import Foreign Configuration" task is unable to
import an inconsistent virtual disk, then the physical disks that
belong to the virtual disk continue to display a "Foreign" state
after the "Import Foreign Configuration" task completes. In this
case, repeat the "Import Foreign Configuration" task until one of
the following occurs:
-- There are no longer any physical disks in "Foreign" state after
the "Import Foreign Configuration" task completes.
-- You receive an error stating that the "Import Foreign
Configuration" task has not completed successfully. This error
indicates that there are no longer any consistent virtual disks
available to be imported. Therefore, all unimported virtual
disks are inconsistent and you can either perform a
"Clear Foreign Configuration" to remove the virtual disks or
remove the physical disks from the controller.
* On a SAS 6/iR, using the command line interface (CLI) to clear a
foreign configuration displays an error message. (154604)
Problem: When using the following command on a SAS 6/iR controller:
omconfig storage controller action=clearforeignconfig controller=id
a "failure" error message may display even though the command has
completed successfully.
Solution: Verify that the "Clear Foreign Configuration" task
completed successfully by using the Storage Management graphical
user interface (GUI):
1. Expand the SAS 6/iR controller object in the tree view.
2. Select the "Physical Disks" object display under the SAS 6/iR
controller object.