Messages Reference Guide

92
Storage Management Message Reference
2101 Temperature
dropped below
the minimum
warning
threshold
Warn ing /
Non-critical
Cause:
The physical
disk enclosure is too
cool.
Action:
Check if the
thermostat setting is
too low and if the room
temperature is too cool.
Clear Alert
Number:
2353.
Related Alert
Number:
None
LRA Number:
2090
1053
2102 Temperature
exceeded the
maximum
failure
threshold
Critical /
Failure / Error
Cause:
The physical disk
enclosure is too hot. A
variety of factors can
cause the excessive
temperature. For
example, a fan may have
failed, the thermostat
may be set too high, or
the room temperature
may be too hot.
Action:
Check for factors
that may cause
overheating. For
example, verify that the
enclosure fan is working.
You should also check
the thermostat settings
and examine whether the
enclosure is located near
a heat source. Make sure
the enclosure has enough
ventilation and that the
room temperature is not
too hot. See the physical
disk enclosure
documentation for more
diagnostic information.
Clear Alert
Number:
None
Related Alert
Number:
None
LRA Number:
2091
1054
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP