Messages Reference Guide
Storage Management Message Reference
91
2099 Global hot
spare
unassigned
OK / Normal /
Informational
Cause:
A user has
unassigned a physical
disk as a global hot
spare. This alert is for
informational purposes.
Action:
None
Clear Alert
Number:
None
Related Alert
Number:
None
LRA Number:
None
901
2100 Temperature
exceeded the
maximum
warning
threshold
Warning /
Non-critical
Cause:
The physical
disk enclosure is too
hot. A variety of factors
can cause the excessive
temperature. For
example, a fan may have
failed, the thermostat
may be set too high,
or the room temperature
may be too hot.
Action:
Check for
factors that may cause
overheating. For
example, verify that the
enclosure fan is working.
You should also check
the thermostat settings
and examine whether
the enclosure is located
near a heat source. Make
sure the enclosure has
enough ventilation and
that the room
temperature is not too
hot. See the physical
disk enclosure
documentation for more
diagnostic information.
Clear Alert
Number:
2353.
Related Alert
Number:
2112
LRA Number:
2090
1053
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers