Messages Reference Guide
Storage Management Message Reference
85
2081
contd.
Virtual disk
reconfiguratio
n failed
Critical /
Failure / Error
Software RAID:
•Perform a backup
with the Verify
option.
• If the file backup
fails, try to restore the
failed file from a
previous backup.
• When the backup
with the Verify option
is complete without
any errors, delete the
Virtual Disk.
• Recreate a new
Virtual Disk with new
drives.
• Restore the data from
backup.
Clear Alert
Number:
None
Related Alert
Number:
None
LRA Number:
2081
1204
2082 Virtual disk
rebuild failed
Critical /
Failure / Error
Cause: A physical disk
included in the virtual
disk has failed or is
corrupt. A user may also
have cancelled
the rebuild.
Action: Replace the
failed or corrupt disk.
You can identify a disk
that has failed by
locating the disk that
has a red “X” for its
status. Restart the
virtual disk rebuild.
Clear Alert
Number:
None
Related Alert
Number: 2048
LRA Number:
2081
1204
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers