Messages Reference Guide

82
Storage Management Message Reference
2075 Copy of data
completed on
physical disk
%2 from
physical disk
%1
OK / Normal /
Informational
Cause: This alert is
provided for
informational purposes.
Action: None
Clear Alert
Number:
None
Related Alert
Number:
2060.
LRA Number:
None
901
2076 Virtual disk
Check
Consistency
failed
Critical /
Failure / Error
Cause: A physical disk
included in the virtual
disk failed or there is an
error in the parity
information. A failed
physical disk can cause
errors in parity
information.
Action: Replace the
failed physical disk. You
can identify which disk
has failed by locating
the disk that has a red
“X” for its status.
Rebuild the physical
disk. When finished,
restart the check
consistency operation.
Clear Alert
Number:
None
Related Alert
Number:
None
LRA Number:
2081
1204
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers