Storage Management Message Reference
2057 Virtual disk
degraded
Warn ing /
Non-critical
Cause 1: This alert
message occurs when a
physical disk included
in a redundant virtual
disk fails. Because the
virtual disk is redundant
(uses mirrored or parity
information) and only
one physical disk has
failed, the virtual disk
can be rebuilt.
Action 1: Configure a
hot spare for the virtual
disk, if one is not
already configured.
Rebuild the virtual disk.
If you are using an
Expandable RAID
Controller (PERC)
PERC 3/SC, 3/DCL,
3/DC, 3/QC, 4/SC,
4/DC, 4e/DC, 4/Di,
CERC ATA100/4ch,
PERC 5/E, PERC 5/i or
a Serial Attached SCSI
(SAS) 5/iR controller,
rebuild the virtual disk
by first configuring a
hot spare for the disk,
and then initiating a
write operation to the
disk. The write
operation initiates a
rebuild of the disk.
Clear Alert
Number:
None
Related Alert
Number:
2048, 2049,
2050, 2076,
2079, 2081,
2123, 2129,
2346
LRA Number:
2080
1203
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers