Table 2-2. Temperature Sensor Messages
Event
ID
Description Severity Cause
1050 Temperature sensor has failed
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not discrete:
Temperature sensor value
(in degrees Celsius): <Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Error A temperature
sensor on the
backplane board,
system board,
or the carrier in the
specified system
failed. The sensor
location, chassis
location, previous
state, and
temperature sensor
value are provided.
1051 Temperature sensor value
unknown
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
If sensor type is not discrete:
Temperature sensor value
(in degrees Celsius): <Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Information A temperature
sensor on the
backplane board,
system board, or
drive carrier in the
specified system
could not obtain a
reading. The sensor
location, chassis
location, previous
state, and
anominal
temperature sensor
value information
is provided.