Messages Reference Guide

Storage Management Message Reference
213
2397 The Check
Consistency
completed
with
uncorrectable
errors
Critical /
Failure / Error
Cause:
The
Check
Consistency
task
detected uncorrectable
multiple errors.
Action:
Replace the
failed physical disk. You
can identify the failed
disk by locating the disk
that has a red “X” for its
status. Rebuild the
physical disk. When
finished, restart the
check consistency
operation.
Clear Alert:
None
Related Alert:
None
LRA Number:
None
1204
2398 The Manage
Physical Disk
Power
property(s)
changed
OK / Normal /
Informational
Cause:
The Manage
Physical Disk Power
properties are changed.
Action:
None
Clear Alert:
None
Related Alert:
None
LRA Number:
None
901
2399 The Physical
Disk Power
status changed
from 1% to 2%
OK / Normal /
Informational
Cause:
The physical
disk power status is
changed from one state
to another. A physical
disk can have the
following power
statuses: spun down,
transition, and spun up.
Action:
None
Clear Alert:
None
Related Alert:
None
LRA Number:
None
901
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers