Messages Reference Guide

208
Storage Management Message Reference
2381 Controller
preserved
cache is
recovered.
OK / Normal /
Informational
Cause:
This alert is
provided for
informational purposes.
Action:
None
Clear Alert:
None
Related Alert:
None
LRA Number:
None
751
2382 An un-
supported
configuration
was detected.
The controller
does not
support
physical disks
of type SSD:
<Physical
DiskID>,
<controller-
ID>,
<connector-
ID>
Warn ing /
Non-critical
Cause:
A physical disk
of media type SSD is
attached to a controller
that does not support
SSD disks.
Action:
Replace the
unsupported physical
disk with a physical disk
of media type HDD.
Clear Alert:
None
Related Alert:
None
LRA Number:
None
903
2383 The
Information
level set for the
hot spare
protection
policy is
violated for the
Virtual Disk.
OK / Normal /
Informational
Cause:
The number of
physical disks you
specified for the hot
spare protection policy
is violated.
Action:
Reassign the
number of hot spares as
specified in the
protection policy for
that RAID level.
Clear Alert:
None
Related Alert:
None
LRA Number:
None
1201
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers