2270 The physical
disk Clear
operation
failed.
Critical /
Failure / Error
Cause:
A Clear task was
being performed on a
physical disk but the
task was interrupted
and did not complete
successfully. The
controller may have lost
communication with
the disk. The disk may
have been removed or
the cables may be loose
or defective.
Action:
Verify that the
disk is present and not
in a
Failed
state. Make
sure the cables are
attached securely. See
the online help for more
information on
checking the cables.
Restart the Clear task.
Clear Alert:
None
Related Alert:
None
LRA Number:
2071
904
2271 The Patrol
Read
encountered a
media error.
OK / Normal /
Informational
Cause:
The Patrol Read
task has encountered an
error such as a bad disk
block that cannot be
remapped. This alert is
for informational
purposes.
Action:
None
Clear Alert:
None
Related Alert:
None
LRA Number:
None
901
Table 3-4. Storage Management Messages