Storage Management Message Reference
2205 A dedicated
hot spare has
been
automatically
unassigned.
OK / Normal /
Informational
Cause:
The hot spare is
no longer required
because the virtual disk
it was assigned to has
been deleted.
None
Clear Alert:
None
Related Alert
Number:
2098, 2161,
2196
LRA Number:
None
901
2210 Battery
requires
reconditioning.
Initiate the
battery learn
cycle.
Warn ing /
Non-critical
Cause:
Battery requires
reconditioning.
Action:
Initiate the
battery learn cycle.
Clear Alert:
None
Related Alert:
None
LRA Number:
2070
1153
2211 The physical
disk is not
supported.
Warn ing /
Non-critical
Cause:
The physical
disk may not have a
supported version of the
firmware or the disk
may not be supported
by Dell.
Action:
If the disk is
supported by Dell,
update the firmware to
a supported version. If
the disk is not
supported by Dell,
replace the disk with
one that is supported.
Clear Alert:
None
Related Alert:
None
LRA Number:
2070
903
Table 3-4. Storage Management Messages