Messages Reference Guide
136
Storage Management Message Reference
2190 The controller
has detected a
hot-plugged
enclosure.
OK / Normal /
Informational
Cause:
The SAS
controller with firmware
version 6.1 or later has
detected a hot-plugged
enclosure. This alert is
for informational
purposes.
Action:
None
Clear Alert:
None
Related Alert:
None
LRA Number:
None
751
2191 Multiple
enclosures are
attached to the
controller. This
is an
unsupported
configuration.
Critical /
Failure / Error
Cause:
There are too
many enclosures
attached to the
controller port. When
the enclosure limit is
exceeded, the controller
loses contact with all
enclosures attached to
the port.
Action:
Remove the last
enclosure. You must
remove the enclosure
that has been added last
and is causing the
enclosure limit to
exceed.
Clear Alert:
None
Related Alert
Number:
2211
LRA Number:
2091
854
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP