Command Line Interface Guide
omconfig storage Commands 251
Example for SCSI, SATA, and ATA Controllers
To blink the LEDs for the enclosure attached to connector 2 on controller 1,
type:
omconfig storage enclosure action=blink
controller=1 enclosure=2
Example for SAS Controllers
To blink the LEDs for enclosure 3 attached to connector 2 on controller 1,
type:
omconfig storage enclosure action=blink
controller=1 enclosure=2:3
omconfig Battery Commands
The following sections provide the omconfig command syntax required to
execute battery tasks.
omconfig Start Battery Learn Cycle
Use the following omconfig command to start the battery learn cycle.
Complete Syntax
omconfig storage battery action=startlearn
controller=id battery=id
where id is the controller ID and battery ID as reported by the omreport
command. To obtain this value, type omreport storage controller to display
the controller IDs and then type omreport storage battery controller=ID to
display the ID for the controller battery.
Table 8-11. omconfig Battery Commands
Required Command Levels (1, 2, 3) Optional name=value pairs
omconfig storage battery
action=startlearn controller=id battery=id
action=delaylearn controller=id battery=id
days=d hours=h