Command Line Interface Guide

omconfig storage Commands 223
In some circumstances, you may receive a warning message if this command
deletes the system or boot partition. You can override this warning by using
the force=yes parameter. In this case, the syntax is as follows:
omconfig storage controller action=resetconfig
controller=id force=yes
Example Syntax
To reset the configuration on controller 1, type:
omconfig storage controller action=resetconfig
controller=1
omconfig Create Virtual Disk
The Dell OpenManage Online Help provides additional information about
creating virtual disks.
The omconfig syntax for creating a virtual disk has several parameters.
You must specify the following parameters:
Controller (controller=id)
RAID level (raid=<c| r0| r1| r1c| r5|r6| r10| r50|r60>)
Size (size=<number | max | min>)
Physical disk is specified as either:
For SCSI, SATA, and ATA Controllers
p
disk=connector:enclosureID:targetID
where connector:enclosureID:targetID is the connector number, enclosure
number, and slot number.
For example pdisk=0:1:2
For SAS Controllers
pdisk=connector:targetID
where connectorID:targetID is the connector number and the slot number.
For example: pdisk=0:2