Command Line Interface Guide

118 omconfig: Managing Components
The output of the omconfig chassis remoteaccess or omconfig mainsystem
remoteaccess command lists each of the available configurations. Table 4-11
shows the valid parameters:
Table 4-11. omconfig chassis remoteaccess/omconfig mainsystem
remoteaccess
name=value pair 1
config=
name=value pair 2 Description
config=
additional
ipv4=enable | disable enable: IPv4 stack to load on iDRAC6.
disable: IPv4 stack to flush on iDRAC6.
ipv6=enable | disable enable: Enables IPv6 stack to load on
iDRAC6.
disable: Disables IPv6 stack to unload
on iDRAC6.
config=advsol characcuminterval=
number
number: Sets the character accumulate
interval in 5 millisecond intervals.
charsendthreshold=
number
number: Sets the number of characters.
BMC automatically sends a serial over
LAN data packet that contains the
number of characters as soon as this
number of characters (or greater) has
been accepted from the baseboard serial
controller into the BMC.
config=nic enable=true | false true: Enables IPMI over LAN.
false: Disables IPMI over LAN.
nicselection=
sharedwithfailoveronall |
nic1 | teamednic1nic2 |
dracnic
sharedwithfailoveronall: Configures the
new NIC selection option.
nic1: Enables NIC 1.
teamednic1nic2: Enables NIC teaming
functionality.
dracnic: Enables DRAC NIC if DRAC 5
is installed.
NOTE: The nicselection option is
supported only on PowerEdge x9xx
systems.
altdnsserverv6 Validates the address of the alternate
DNS server for configuration.