Command Line Interface Guide

omconfig: Managing Components 111
Index 0 always defaults to the main system chassis. The following command
omits index=n, but accomplishes the same thing:
omconfig chassis info tag=buildsys
or
omconfig mainsystem info tag=buildsys
An acceptable command, when executed, results in the following message:
Chassis info set successfully.
For some chassis, you can assign a different name. You cannot rename the
main system chassis. In the example below, the command renames chassis 2
from storscsi1 to storscsia:
omconfig chassis info index=2 name=storscsia
or
omconfig mainsystem info index=2 name=storscsia
As with other commands, the CLI issues an error message if you do not have a
chassis 2 (the main chassis=0). The CLI allows you to issue commands only
for the system configuration you have.
omconfig chassis leds/omconfig mainsystem leds
Use the omconfig chassis leds or omconfig mainsystem leds command to
specify when to flash a chassis fault LED or chassis identification LED.
This command also allows you to clear the LED of the system hard drive.
Table 4-7 shows the valid parameters for the command.
Table 4-7. omconfig chassis leds/omconfig mainsystem leds
name=value pair 1 name=value pair 2 Description
index=<n> NA Number of the chassis where the LED
resides (defaults to chassis 0, main system
chassis).
led=fault severity=warning |
critical
Select to flash the LED either when a
warning event occurs or when a critical
event occurs.
led=hdfault action=clear Sets the number of faults for the hard
drive back to zero (0).
led=identify flash=off | on
time-out=<n>
Sets the chassis identification LED to off
or on. Set the time-out value for the LED
to flash to a number of seconds.