Users Guide
Server Administrator Services 77
embedded hypervisor and additional LAN network ports on motherboard
information. You can view the settings of Trusted Platform Module (TPM)
and Trusted Cryptographic Module (TCM).
Depending upon your specific system configuration, additional setup items
may be displayed. However, some BIOS setup options may be shown on the
F2 BIOS Setup screen that are not accessible in Server Administrator.
NOTE: The NIC configuration information within the Server Administrator BIOS
setup may be inaccurate for embedded NICs. Using the BIOS setup screen to
enable or disable NICs might produce unexpected results. It is recommended that
you perform all configurations for embedded NICs through the actual System Setup
screen that is available by pressing <F2> while a system is booting.
NOTE: The BIOS Setup tab for your system only displays the BIOS features that are
supported on your system.
Fans
Click the Fans object to manage your system fans. Server Administrator
monitors the status of each system fan by measuring fan rpms. Fan probes
report rpms to the Server Administrator Instrumentation Service. When you
select Fans from the device tree, details appear in the data area in the
right-hand pane of the Server Administrator home page. The Fans object
action window can have the following tabs, depending on the user's group
privileges: Properties and Alert Management.
Properties
Subtab: Fan Probes
Under the Properties tab, you can:
• View the current readings for your system's fan probes and configure
minimum and maximum values for fan probe warning threshold.
NOTE: Some fan probe fields differ according to the type of firmware your
system has: BMC or ESM. Some threshold values are not editable on
BMC-based systems.
• Select fan control options.
Alert Management
Subtabs: Alert Actions | SNMP Traps
Under the Alert Management tab, you can:
book.book Page 77 Monday, November 29, 2010 4:40 PM