Owner's Manual

252 omconfig storage Commands
Complete Syntax
omconfig storage battery action=delaylearn
controller=id battery=id days=d hours=h
where id is the controller ID and battery ID as reported by the omreport
command. To obtain this value, type omreport storage controller to display
the controller IDs and then type omreport storage battery controller=ID to
display the ID for the controller battery.
Example Syntax
To delay the learn cycle for three days and 12 hours on controller 1, type:
omconfig storage battery action=delaylearn
controller=1 battery=0 days=3 hours=12
omconfig Global Commands
The following sections provide the omconfig command syntax required to
execute the global commands. When executed, these commands apply to all
controllers. These global commands also correspond to the global tasks
provided by the Storage tree view object’s Information/Configuration
subtab.
omconfig Global Enable Smart Thermal Shutdown
By default, the operating system and server shut down when the PV220S and
PV221S enclosures reach a critical temperature of 0 or 50° Celsius. However,
if you have implemented
connector redundancy on the PV220S and PV221S
enclosures you can specify that only the enclosure and not the operating
system and server be shut down when the enclosure reaches a critical
Table 8-12. omconfig Global Commands
Required Command Levels (1, 2, 3) Optional name=value pairs
omconfig storage globalinfo
action=enablests
action=disablests
action=globalrescan
action=setprotectionpolicies type=ghs or dhs