244 omconfig storage Commands
omconfig Enable Enclosure Alarm
Use the following omconfig command syntax to enable the enclosure alarm:
Complete Syntax
omconfig storage enclosure action=enablealarm
controller=id enclosure=<ENCLOSUREID>
where id is the controller ID. The <ENCLOSUREID> variable specifies the
enclosure.
Table 8-10. omconfig Enclosure Commands
Required Command Levels (1, 2, 3) Optional name=value pairs
omconfig storage enclosure
action=enablealarm controller=id enclosure=
<ENCLOSUREID>
action=disablealarm controller=id enclosure=
<ENCLOSUREID>
action=setassettag controller=id enclosure=
<ENCLOSUREID> assettag=<string>
action=setassetname controller=id enclosure=
<ENCLOSUREID> assetname=<string>
action=settempprobes controller=id enclosure=
<ENCLOSUREID> index=id minwarn=n
maxwarn=n
action=resettempprobes controller=id enclosure=
<ENCLOSUREID> index=id
action=setalltempprobes controller=id
enclosure=<ENCLOSUREID> minwarn=n
maxwarn=n
action=resetalltempprobes controller=id
enclosure=<ENCLOSUREID>
action=blink controller=id
enclosure=<ENCLOSUREID>