User's Manual

38 omreport: Viewing System Status Using the Instrumentation Service
Server Administrator displays a general status for your main system
chassis/main system components.
omreport chassis acswitch/omreport mainsystem acswitch
Use the omreport chassis acswitch or omreport mainsystem acswitch
command if your system has redundant AC power lines that are configured in
a failover arrangement. Type:
omreport chassis acswitch
or
omreport mainsystem acswitch
Server Administrator displays the following output:
SEVERITY : COMPONENT
Ok : Fans
Critical : Intrusion
Ok : Memory
Ok : Power Supplies
Ok : Temperatures
Ok : Voltages
AC Failover Switch
AC Switch Redundancy
Redundancy Status : Full
Number of devices
required for full
redundancy
:2
Redundancy Mode :
Redundancy
Configuration
: Input Source Line 1, upon
redundancy restoration,
return to Line 1
AC Power Lines
Status : Ok
Location : AC Power Line 1
AC Present : Power Present
Active Source : Active
Status : Ok