User's Manual
224 Using the Storage Management Service
omconfig Blink Physical Disk
You can blink the light (light emitting diode or LED display) on one or more
physical disks attached to a controller. Use the following omconfig command
syntax to blink one or more physical disks.
Complete Syntax
action=blink controller=id pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the physical
disk.
To obtain these values, type omreport storage controller to display the
controller IDs and then type omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, you want to blink physical disk 0 on connector 0 of controller 1.
On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers
To blink the physical disk described in this example, type:
omconfig storage pdisk action=blink controller=1
pdisk=0:0
Example for SAS Controllers
To blink the physical disk described in this example, type:
omconfig storage pdisk action=blink controller=1
pdisk=0:2:0
action=cancelreplacemember controller=id pdisk=
<PDISKID>
action=instantsecureerase controller=id pdisk=
<PDISKID>
Table 6-24. omconfig Physical Disk Commands
(continued)
Required Command Levels
(1, 2, 3)
Optional name=value pairs