User's Manual
194 Using the Storage Management Service
Complete Syntax
omconfig storage controller action=createvdisk
controller=id raid=<c| r0| r1| r1c| r5| r6| r10| r50
|r60> size=<number | max | min> pdisk=<PDISKID>
[stripesize=< 2kb| 4kb| 8kb| 16kb| 32kb| 64kb|
128kb>] [cachepolicy=<d | c>] [diskcachepolicy=
<disabled | enabled>][readpolicy=<ra | nra | ara |
rc| nrc>] [writepolicy=<wb| wt| wc| nwc | fwb>]
[name=<string>] [spanlength=<n>] |
[secureflag=yes]
NOTE: If you are configuring RAID for SAS controllers with firmware version 6.1
and later, spanlength is an optional parameter (default=2). Spanlength should be an
even number and should be lesser than or equal to half the number of physical disks
specified in size.
Parameter Specification for Create and Reconfigure Virtual Disk
The following sections indicate how to specify the omconfig storage controller
action=createvdisk parameters.
controller=id Parameter (Required)
raid=<c| r0| r1| r1c| r5| r6| r10| r50| r60> Parameter (Required)
size=<number | max | min> Parameter (Required)
pdisk=<connector:targetID,connector:targetID,.....> Parameter
(Required)
[stripesize=< 2kb| 4kb| 8kb| 16kb| 32kb| 64kb| 128kb>] Parameter
(Optional)
[cachepolicy=<d | c>] Parameter (Optional)
[readpolicy=<ra| nra| ara| rc| nrc>] Parameter (Optional)
[writepolicy=<wb| wt| wc| nwc | fwb>] Parameter (Optional)
[name=<string>] Parameter (Optional)
[spanlength=<n>] Parameter (Optional)
controller=id Parameter (Required)
Specify the controller ID as reported by the omreport storage controller
command. For example:
controller=2