User's Manual
190 Using the Storage Management Service
omconfig Rescan Controller
Use the following omconfig command syntax to rescan a controller.
See Dell OpenManage Online Help for more information about Rescan
Controller.
Complete Syntax
omconfig storage controller action=rescan
controller=id
where id is the controller ID as reported by the omreport storage controller
command.
Example Syntax
To rescan controller 1, type:
omconfig storage controller action=rescan
controller=1
NOTE: The rescan controller is not supported on non–RAID SCSI and SAS
controllers. Reboot the system for the configuration changes on non-RAID SCSI
controllers to be visible.
omconfig Enable Controller Alarm
Use the following omconfig command syntax to enable the controller alarm.
See the Dell OpenManage Online Help for more information about Enable
Controller Alarm.
Complete Syntax
omconfig storage controller action=enablealarm
controller=id
where id is the controller ID as reported by the omreport storage controller
command.
Example Syntax
To enable the alarm on controller 1, type:
omconfig storage controller action=enablealarm
controller=1