User's Manual

omconfig: Managing Components Using the Instrumentation Service 149
Table 4-31 shows the valid parameters for the command.
Example Thermal Shutdown Commands
To trigger a thermal shutdown when a temperature probe detects a failure
event, type:
omconfig system thrmshutdown severity=failure
or
omconfig servermodule thrmshutdown severity=
failure
To disable thermal shutdown so that an administrator has to initiate an
omconfig system shutdown, type:
omconfig system thrmshutdown severity=disabled
or
omconfig servermodule thrmshutdown severity=
disabled
Table 4-31. Thermal Shutdown Parameters
name=value
pair
Description
severity=
disabled |
warning |
failure
disabled: Disable thermal shutdown. An administrator must intervene.
warning: Perform a shutdown when a temperature warning event is
detected. A warning event occurs when any temperature probe inside a
chassis reads a temperature (in degrees Celsius) that exceeds the
maximum temperature warning threshold value.
failure: Perform a shutdown when a temperature failure event is
detected.
A failure event occurs when any temperature probe inside a chassis
reads a temperature (in degrees Celsius) that exceeds the maximum
temperature failure threshold value.