User's Manual

146 omconfig: Managing Components Using the Instrumentation Service
omconfig system events type=fan index=0 severity=
critical
or
omconfig servermodule events type=fan index=0
severity=critical
As a result of the example command, Server Administrator sends an SNMP
trap only when the first fan in the system chassis (index 0) has reached critical
fan RPMs.
omconfig system webserver/omconfig servermodule webserver
Use the omconfig system webserver or omconfig servermodule webserver
command to start or stop the Web server. Table 4-28 shows the valid
parameters for the command.
omconfig system recovery/omconfig servermodule recovery
Use the omconfig system recovery or omconfig servermodule recovery
command to set the action to be taken when the operating system has hung
or crashed. You can also set the number of seconds that must pass before the
system is considered to have a hung operating system. Table 4-29 shows the
valid parameters for the command.
NOTE: Upper and lower limits for the timer are dependent on your system model
and configuration.
Table 4-28. Web Server Configuration Parameters
name=value pair Description
action=start Starts the Web server.
action=stop Stops the Web server.
action=restart Restarts the Web server.
Table 4-29. Recovery Parameters
name=value pair Description
action=none Takes no action when the operating system is hung or has
crashed.
action=reboot Shuts down the operating system and initiates system startup,
performing BIOS checks, and reloading the operating system.