User's Manual

142 omconfig: Managing Components Using the Instrumentation Service
event=intrusion Sets action or enables/disables alert generation when a
chassis is opened.
event=powerwarn Sets action or enables/disables alert generation when a
power device probe detects that the power supply,
voltage regulator module, or DC to DC converter is
pending a failure condition.
event=powerabsent Sets action or enables/disables alert generation when a
processor probe detects that the power supply is absent.
event=powerfail Sets action or enables/disables alert generation when a
power device probe detects that the power supply,
voltage regulator module, or DC to DC converter has
failed.
event=processorwarn Sets action or enables/disables alert generation when a
processor probe detects that the processor is running at
less than peak performance or speed.
event=processorfail Sets action or enables/disables alert generation when a
processor probe detects that the processor has failed.
event=processorabsent Sets action or enables/disables alert generation when a
processor probe detects that the processor is absent.
event=redundegrad Sets action or enables/disables alert generation when
the system’s fans and/or power supplies become
inoperative, resulting in less than full redundancy for
that component.
event=redunlost Sets action or enables/disables alert generation when
the system’s fans and/or power supplies become
inoperative, resulting in a lost or a "no redundant
components working" condition for that component.
event=systempowerwarn Sets actions when a power consumption probe detects
a warning value.
event=systempowerfail Sets actions when a power consumption probe detects
a failure value.
event=tempwarn Sets action or enables/disables alert generation when a
temperature probe detects that the temperature is
approaching the maximum high or low limits.
Table 4-25. omconfig system platformevents
(continued)
Event Name Description