User's Manual
omconfig: Managing Components Using the Instrumentation Service 141
Table 4-25 lists the components and the events for which you can set
platform events. Components are listed in alphabetical order, except that
warning events always precede failure events for a component.
action=
powerreduction
Reduces the processor speed until the power consumption
comes down and reaches below the warning threshold. If the
system power consumption stays below the warning
threshold, increases the processor speed
NOTE: This action is applicable only to non–modular systems.
action=reboot Forces the operating system to shut down and initiates system
startup, performs BIOS checks, and reloads the operating
system.
Table 4-25. omconfig system platformevents
Event Name Description
alertsenable=true | false true: Enables generation of platform event filter alerts.
false: Disables generation of platform event filter alerts.
NOTE: This setting is independent of the individual
platform event filter alert settings. For a platform event
filter to generate an alert, both the individual alert and the
global event alert must be enabled.
event=batterywarn Sets action or enables/disables alert generation when a
battery device detects that the battery is pending a
failure condition.
event=batteryfail Sets action or enables/disables alert generation when a
battery device detects that the battery has failed.
event=discretevolt Sets action or enables/disables alert generation when a
discrete voltage probe detects that the voltage is too
low for proper operation.
event=fanfail Sets action or enables/disables alert generation when a
fan probe detects that the fan is running too slow or not
at all.
event=hardwarelogfail Enables/disables alert generation when a hardware log
detects a failure value.
Table 4-24. Parameters for Alert Action Command
(continued)
Action Description