User's Manual
omconfig: Managing Components Using the Instrumentation Service 137
NOTE: storagectrlbatterywarn and storagectrlbatteryfail events are not available
on modular systems.
Example Set Alert Action Commands
The examples below are valid example commands. For each successful
command issued, the following message appears:
Alert action(s) configured successfully.
event=watchdogasr Sets actions that Server Administrator performs on the
next system startup after a watchdog Automatic System
Recovery (ASR) is performed for a hung operating system.
event=
removableflashmediapresent
Sets actions that Server Administrator performs when the
system detects a removable flash media.
event=
removableflashmediaremoved
Sets actions that Server Administrator performs when a
removable flash media is removed.
event=
removableflashmediafail
Sets actions that Server Administrator performs when a
removable flash media fails.
event=storagesyswarn Sets actions when a storage system detects a warning
value.
event=storagesysfail Sets actions when a storage system detects a failure value.
event=storagectrlwarn Sets actions when a storage controller detects a warning
value.
event=storagectrlfail Sets actions when a storage controller detects a failure
value.
event=pdiskwarn Sets actions when a physical disk detects a warning value.
event=pdiskfail Sets actions when a physical disk detects a failure value.
event=vdiskwarn Sets actions when a virtual disk detects a warning value.
event=vdiskfail Sets actions when a virtual disk detects a failure value.
event=enclosurewarn Sets actions when an enclosure detects a warning value.
event=enclosurefail Sets actions when an enclosure detects a failure value.
event=storagectrlbatterywarn Sets actions when a storage controller battery detects a
warning value.
event=storagectrlbatteryfail Sets actions when a storage controller battery detects a
failure value.
Table 4-22. Events for Which You Can Set Alert Actions
(continued)
Event Name Description