User's Manual

omconfig: Managing Components Using the Instrumentation Service 105
Specifying a Value for Minimum and Maximum Warning Thresholds
If you prefer to specify values for the fan probe warning thresholds, you must
specify the number of the probe you are configuring and the minimum and/or
maximum warning threshold values. In the following example, the probe that
is being configured is probe 0. The first command sets only the minimum
threshold; the second sets minimum and maximum thresholds:
omconfig chassis fans index=0 minwarnthresh=4580
or
omconfig mainsystem fans index=0 minwarnthresh=
4580
omconfig chassis fans index=0 minwarnthresh=4580
maxwarnthresh=9160
or
omconfig mainsystem fans index=0 minwarnthresh=
4580 maxwarnthresh=9160
When you issue the command and the system sets the values you specify, the
following message appears:
Fan probe warning threshold(s) set successfully.
NOTE: Minimum and maximum warning thresholds for the fan probe cannot be set
on PowerEdge
x
8xx and x9xx systems.
omconfig chassis frontpanel/omconfig mainsystem frontpanel
Use the omconfig chassis frontpanel or omconfig mainsystem frontpanel
command to:
configure the power button and the Nonmasking Interrupt (NMI) button
configure the LCD to display:
No information
Custom information
Default system information
Service tag, system name
Remote access MAC addresses
System power
Remote access IP address