Read me

file:///T|/htdocs/SOFTWARE/svradmin/6.3/en/README/readme.txt[10/26/2012 8:28:05 AM]
the System Setup Program.
* The links on the Server Administrator home page may lock up after
repeated random clicking. To resolve this situation, refresh the
browser by pressing <F5> or click the browser "Refresh" button.
* All unsecured HTTP requests to Server Administrator receive an
invalid response. Server Administrator runs only one instance of
the Web server, which is secure. Make all connections through
https://<ip address> : <port number>. Any "http://<ip address>:
<port number>" request for connection with the server receives an
invalid response.
* If the browser used with Server Administrator indicates that it
cannot display a page or perform an action, ensure that the browser
is in online mode. To go online, perform the following:
- If you are using Internet Explorer, click "File" on the
menu bar and deselect the "Work Offline" option. When "Work
Offline" is selected, a check displays to the left of the option
on the "File" menu.
* If Internet Explorer prompts you to "Work Offline", "Connect", or
"Try Again", always select "Connect" or "Try Again". Do not select
"Work Offline".
* When setting dates in the "Asset Information" section of the Server
Administrator home page, the current time is appended to the date.
When setting dates with the CLI, the appended time is noon.
* On some systems, temperature probe values and settings are only
supported for whole degrees, not tenths of a degree. On these
systems, setting a fractional value for the minimum warning
temperature threshold results in the set value being rounded down
to the next whole number value. This behavior may cause the minimum
warning threshold to have the same value as the minimum failure
threshold.
* If you close the browser using browser "Close" button or logs off
from the Operating System, the Server Administrator session does not get
terminated. This session will be listed in the Session Management
page until the session time out occurs or DSM SA connection service
is restarted or the OS is rebooted. The maximum number of Server
Administrator sessions at a time is configured by "connections"
entry in "<OpenManageInstallPath>\iws\config\iws.ini" file.
* If you change the operating system timezone to a new timezone,
Server Administrator session management will not display the time
in the new time zone specified. Restart the Server Administrator
so that the correct time zone time is displayed in the
Session Management page.
* Server Administrator Auto Recovery feature may execute configured
action when system is under heavy stress.