Users Guide
You may also want to refer to the following related sections:
l "What Is RAID?"
l "Channel Redundancy and Thermal Shutdown" for information on creating a channel-redundant virtual disk
l "Virtual Disk Task: Delete"
l "Reconfiguring/Migrating Virtual Disks"
l "Physical Disk Properties and Tasks"
Reconfiguring/Migrating Virtual Disks
Does my controller support this feature? See "Supported Features."
You can reconfigure or migrate a virtual disk in order to increase the disks capacity or change its RAID level.
To reconfigure a virtual disk:
1. Review the information in "Starting and Target RAID Levels for Virtual Disk Reconfiguration and Capacity Expansion."
2. Locate the controller on which the virtual disk resides in the tree view. Expand the controller object until the Virtual Disks object is displayed.
3. Select the Reconfigure task from the virtual disk's drop-down menu and click Execute.
4. Complete the Reconfigure task using the Reconfigure wizard. See "Virtual Disk Task: Reconfigure (Step 2 of 3)" for more information.
Starting and Target RAID Levels for Virtual Disk Reconfiguration and Capacity
Expansion
After you have created a virtual disk, the possibilities for reconfiguring the virtual disk depend on the controller, RAID level, and available physical disks. The
following table describes the possible scenarios for reconfiguring a virtual disk. For more information on the RAID levels, see "Choosing RAID Levels and
Concatenation."
Table 11-1.VirtualDiskReconfigurationandCapacityExpansion
Controller
Starting RAID Level
Target RAID Level
Comments
PERC 3/SC, 3/DC, 3/QC, 4/SC, PERC 4/DC,
PERC 4e/DC, 4/Di, 4e/Si, PERC 4e/Di, CERC
ATA100/4ch, PERC 5/E and PERC 5/i
RAID 0
RAID 0
Add at least one additional disk
PERC 3/SC, 3/DC, 3/QC, 4/SC, PERC 4/DC,
PERC 4e/DC, 4/Di, 4e/Si, PERC 4e/Di, CERC
ATA100/4ch, PERC 5/E and PERC 5/i
RAID 0 (on a single disk)
RAID 1
Add a single disk
PERC 3/SC, 3/DC, 3/QC, 4/SC, 4/DC,
4e/DC, 4/Di, 4e/Si, PERC 4e/Di, CERC
ATA100/4ch, PERC 5/E and PERC 5/i
RAID 0
RAID 5
Add at least one additional disk
PERC 3/SC, 3/DC, 3/QC, 4/SC, PERC 4/DC,
PERC 4e/DC, 4/Di, 4e/Si, PERC 4e/Di, CERC
ATA100/4ch, PERC 5/E and PERC 5/i
RAID 1
RAID 0
With or without adding additional disks
RAID 1
RAID 5
Add additional disks
RAID 5
RAID 0
With or without adding additional disks
RAID 5
RAID 5
Add additional disks
PERC 4/IM
N/A
N/A
N/A
PERC 3/Si, and 3/Di
Concatenation
RAID 1
Minimum number of physical disks required for the
target RAID level must be available
RAID 0
RAID 0, RAID 5, RAID 10
RAID 1
RAID 0, RAID 1, RAID 5, RAID
10
RAID 5
RAID 0, RAID 5, RAID 10
RAID 10
RAID 0, RAID 5, RAID 10
CERC SATA1.5/6ch
Concatenation
RAID 1
Minimum number of physical disks required for the
target RAID level must be available
See "Exceptions for Reconfiguring a Concatenated Virtual
Disk on PERC 3/Si, 3/Di, CERC SATA1.5/6ch, and CERC
SATA1.5/2s Controllers" for more information.
RAID 0
RAID 0, RAID 5, RAID 10
RAID 1
RAID 0, RAID 1, RAID 5, RAID
10
RAID 5
RAID 0, RAID 5, RAID 10