Users Guide
Working with Remote Access Controller 91
• Configure the remote access device on a serial over LAN connection
• Configure the remote access device on a serial port connection
• Configure Additional remote access device properties
• Configure users on the remote access device
• Set platform event filter alerts
You can view BMC/iDRAC or DRAC information based on which hardware is
providing the remote access capabilities for the system.
The reporting and configuration of BMC/iDRAC and DRAC can also be
managed using the omreport/omconfig chassis remoteaccess
CLI command.
In addition, the Server Administrator Instrumentation Service allows you to
manage the Platform Event Filters (PEF) parameters and alert destinations.
NOTE: You can view BMC data on Dell PowerEdge x8xx and x9xx systems only.
Viewing Basic Information
You can view basic information about the BMC/iDRAC, IPv4 Address and
DRAC. You can also reset the BMC settings to their default values. To do this:
NOTE: You must be logged in with Administrator privileges to reset the BMC settings.
1
Click the
Modular Enclosure
→
System/Server Module
→
Main System
Chassis/Main System
→
Remote Access
object.
The
Remote Access
page displays the following base information of the
system’s BMC:
Remote Access Device
• Device type
•IPMI Version
• System GUID
• Number of Possible Active Sessions
• Number of Current Active Sessions
•LAN Enabled
•SOL Enabled
• MAC Address
book.book Page 91 Friday, December 4, 2009 3:20 PM