SNMP Reference Guide
Traps 731
BMC Traps
The BMC monitors the system for critical events by communicating with
various sensors on the system board and by sending alerts and log events
when certain parameters exceed their preset thresholds. All of the traps
documented in this section belong to the MIB enterprise identified by OID
1.3.6.1.4.1.3183.1.1.1.
1020 alertDrscSEL
Normal
The RAC
has
detected a
new event
in the
System
Event Log
with
Severity:
Normal
Information Error RAC
detected a
new system
event log with
normal
severity
(detailed log
info is in
drsAlert
Message
varbind).
All
Table 26-20. BMC Traps
Trap ID Description Severity
262402 Generic Critical Fan Failure Critical
262530 Generic Critical Fan Failure Cleared Informational
131330 Under-Voltage Problem (Lower Critical -
going low)
Critical
131458 Under-Voltage Problem Cleared Informational
131841 Generic Critical Voltage Problem Critical
131840 Generic Critical Voltage Problem
Cleared
Informational
65792 Under-Temperature Warning (Lower non-
critical, going low)
Wa rn in g
Table 26-19. Enterprise-specific Traps
(continued)
Trap
ID
Name Description Severity Category Cause Supported
by RAC
Platform