Read me

file:///T|/htdocs/SOFTWARE/svradmin/6.2/en/README/readme.txt[10/26/2012 3:03:00 PM]
* On certain systems, user-defined thresholds set under Server
Administrator become the default thresholds after uninstalling
Server Administrator.
After you change the threshold value of a probe on certain systems
running Server Administrator and then uninstall Server Administrator,
the changed threshold value becomes the default threshold value.
* When modifying the warning threshold settings, the values are stored
in the firmware as discrete integer values and scaled for display.
If the modified value is not a discrete integer, it may change when
saved.
* Fan redundancy can have the following states:
Fully Redundant: The sensors display this status if all the fans
in the system are present and are in a non-failure state.
OR
Redundancy Lost: The sensors display this status whenever any
system fan fails or is removed from the chassis.
* If a system with memory redundancy enabled enters a "redundancy
lost" state, it may not be apparent which memory module is the
cause. If you cannot determine which DIMM to replace, see the
"switch to spare memory detected" log entry in the ESM system
log to find the memory module that failed.
* If you run Server Administrator while the system is in "OS Install
Mode", memory may be reported incorrectly by Server Administrator.
To avoid this issue, you must disable "OS Install Mode" before
running Server Administrator.
* If you have to uninstall and reinstall the operating system SNMP
service, then reinstall Server Administrator as well, so that the
Server Administrator SNMP agents are registered with the operating
system SNMP agent.
=====================================================================
NOTES FOR THE STORAGE MANAGEMENT SERVICE
=====================================================================
* When using the Storage Management Service, Stop the DSM SA Data
Manager Services before updating the Adaptec(R) Controllers.
* Detailed information on the Storage Management Service is available
in the Storage Management Service online help. After installing and
launching Server Administrator, you can access the Storage
Management Service online help by selecting the Storage or
lower-level tree object and clicking the Help button on the global
navigation bar.