Read me
file:///T|/htdocs/SOFTWARE/svradmin/6.2/en/README/readme.txt[10/26/2012 3:03:00 PM]
and "Open in New Window" may not be supported.
* Selecting the boot sequence under the BIOS "Setup" tab does not
re-enable boot devices that have been previously disabled in
the System Setup Program.
* The links on the Server Administrator home page may lock up after
repeated random clicking. To resolve this situation, refresh the
browser by pressing <F5> or click the browser "Refresh" button.
* All unsecured HTTP requests to Server Administrator receive an
invalid response. Server Administrator runs only one instance of
the Web server, which is secure. Make all connections through
https://<ip address> : <port number>. Any "http://<ip address>:
<port number>" request for connection with the server receives an
invalid response.
* If the browser used with Server Administrator indicates that it
cannot display a page or perform an action, ensure that the browser
is in online mode. To go online, perform the following:
- If you are using Internet Explorer, click "File" on the
menu bar and deselect the "Work Offline" option. When "Work
Offline" is selected, a tick mark displays to the left of the option
on the "File" menu.
* If Internet Explorer prompts you to "Work Offline", "Connect", or
"Try Again", always select "Connect" or "Try Again". Do not select
"Work Offline".
* When setting dates in the "Asset Information" section of the Server
Administrator home page, the current time is appended to the date.
When setting dates with the CLI, the appended time is noon.
* If Network Adapter Teaming is installed and enabled on your system,
Server Administrator does not display the IP address or other
connection-related data for the individual network adapters. The
connection status and IP address belong to the virtual adapter
created by the teaming software.
* On some systems, temperature probe values and settings are only
supported for whole degrees, not tenths of a degree. On these
systems, setting a fractional value for the minimum warning
temperature threshold results in the set value being rounded down
to the next whole number value. This behavior may cause the minimum
warning threshold to have the same value as the minimum failure
threshold.
* Some Internet browsers (for example, Microsoft Internet Explorer, Mozilla
Firefox, and so on) share states, including cookies and browser session
information, across multiple instances. If a user tries to log in
to multiple browser instances, then only the last session stays
active, while the older sessions expire. As a result, the
“403 forbidden” error message could be displayed in the older