User's Manual
48 omreport: Viewing System Status Using the Instrumentation Service
The following is an example output:
omreport chassis memory/omreport mainsystem memory
Use omreport chassis memory or omreport mainsystem memory to view
details for each memory module slot in your system. If your system supports
redundant memory, this command also displays the status, state, and type of
memory redundancy implemented on your system. Type:
omreport chassis memory index=
n
or
omreport mainsystem index=
n
The index parameter is optional. If you do not specify the index, Server
Administrator displays information for all memory modules on your system.
If you specify the index, Server Administrator displays a summary for a
specific memory module.
Output for an occupied memory slot may resemble the following:
An unoccupied memory slot still has a connector name. Output for an
unoccupied memory slot may resemble the following:
Flash chassis indentify LED state
Flash chassis indentify LED timeout
value
: Off
: 300
Index
Status
Connector Name
Type
Size
: 1
: OK
: DIMM_B
: SDRAM-SYNCHRONOUS
: 256 MB
Index
Status
Connector Name
Type
Size
: 2
: Unknown
: DIMM_D
: Not Occupied
: Unknown