User's Manual

omreport: Viewing System Status Using the Instrumentation Service 47
omreport chassis intrusion
Use the omreport chassis intrusion command to find out whether the cover
of your system is open or not. Server Administrator tracks chassis intrusion
events because intrusions may indicate an attempt to steal a system
component, or to perform unauthorized maintenance on the system. Type:
omreport chassis intrusion
A message that resembles the following displays:
omreport chassis leds/omreport mainsystem leds
Use the omreport chassis leds or omreport mainsystem leds command to find
out whether clear hard drive fault is supported and what severity level lights
up the LED. Type:
omreport chassis leds index=
n
or
omreport mainsystem leds index=
n
The index parameter is optional. If you do not specify the index, Server
Administrator displays a summary of LED information for chassis 0. If you
specify the index, Server Administrator displays a summary for a specific
chassis.
Chassis Lock : Present
Chassis Service Tag : 8RLNB1S
Chassis Asset Tag :
Flash chassis indentify LED state : Off
Flash chassis indentify LED
timeout value
: 300
Status
Probe Name
State
: Ok
: Main chassis intrusion
: Chassis is closed