User's Manual
Using the Storage Management Service 181
Complete Syntax
For dedicated hot spare protection policy, type:
omconfig storage globalinfo action=
setprotectionpolicies type=dhs raid=<r1 | r5 | r6 |
r10 | r50 | r60 | all> hscount=<1-16> warnlevel=<0-3>
where hscount is the number of hot spares to be assigned to the virtual disk
and warnlevel is the severity level you want to assign to the generated
alert, if this policy is violated. Use hscount=0 warnlevel=0 to reset the
dedicated hot spare protection policy for the RAID level.
For global hot spare protection policy, type:
omconfig storage globalinfo action=
setprotectionpolicies type=ghs hscount=<1-16>
warnlevel=<0-3> includeghsinvdstate=<yes | no>
where hscount is the number of hot spares to be assigned to the virtual disk
and
warnlevel
is the severity level you want to assign to the generated alert,
if this policy is violated. Use
hscount=0 warnlevel=0
to reset the global
hot spare protection policy for the RAID level.
omconfig Controller Commands
The following sections provide the omconfig command syntax required to
execute controller tasks.
CAUTION: The omconfig storage controller action=resetconfig controller=id
resets the controller configuration. Resetting the controller configuration
permanently destroys all data on all virtual disks attached to the controller. System
or boot partition residing on these virtual disks will be destroyed.
Table 6-16. omconfig Controller Commands
Required Command
Levels (1, 2, 3)
Optional name=value pairs
omconfig storage
controller
action=rescan controller=id
action=enablealarm controller=id
action=disablealarm controller=id