User's Manual

180 Using the Storage Management Service
Complete Syntax
omconfig storage globalinfo action=disablests
Example Syntax
The omconfig command syntax for disabling thermal shutdown does not
require that you specify a controller or enclosure ID. To disable thermal
shutdown, enter the following:
omconfig storage globalinfo action=disablests
NOTE: You can use the omreport storage globalinfo command to determine
whether smart thermal shutdown is currently enabled or disabled. The status of
smart thermal shutdown is also displayed in the GUI of Server Administrator. To
locate this status, select the Storage object and the Information/Configuration tab.
omconfig Global Rescan Controller
Use the following omconfig command syntax to rescan all controllers on the
system. See the Dell OpenManage Online Help for more information about
Global Rescan Controller.
Complete Syntax
omconfig storage globalinfo action=globalrescan
Example Syntax
The omconfig command syntax for rescanning all controllers on the system
does not require that you specify a controller ID. To do a global rescan of all
controllers, enter the following:
omconfig storage globalinfo action=globalrescan
NOTE: Global rescan is not supported on non-RAID SCSI and SAS controllers.
Reboot the system for the configuration changes on non-RAID SCSI controllers to
be visible.
omconfig Set Hot Spare Protection Policy
Use the following omconfig command syntax to set the Hot Spare Protection
Policy for dedicated or global hot spares. See the Dell OpenManage Server
Administrator Storage Management User’s Guide for more information on
setting hot spare protection policy.