User's Manual

omconfig: Managing Components Using the Instrumentation Service 137
Table 4-26 lists the components and the events for which you can set
platform events. Components are listed in alphabetical order, except that
warning events always precede failure events for a component.
action=
powerreduction
Reduces the processor speed until the power consumption
comes down and reaches below the warning threshold. If the
system power consumption stays below the warning
threshold, increases the processor speed
NOTE: This action is applicable only to non–modular systems.
action=reboot Forces the operating system to shut down and initiates system
startup, performs BIOS checks, and reloads the operating
system.
Table 4-26. omconfig system platformevents
Event Name Description
alertsenable=true |
false
true: Enables generation of platform event filter alerts.
false: Disables generation of platform event filter alerts.
NOTE: This setting is independent of the individual platform
event filter alert settings. For a platform event filter to generate
an alert, both the individual alert and the global event alert
must be enabled.
event=batterywarn Sets action or enables/disables alert generation when a
battery device detects that the battery is pending a failure
condition.
event=batteryfail Sets action or enables/disables alert generation when a
battery device detects that the battery has failed.
event=discretevolt Sets action or enables/disables alert generation when a
discrete voltage probe detects that the voltage is too low for
proper operation.
event=fanfail Sets action or enables/disables alert generation when a fan
probe detects that the fan is running too slow or not at all.
event=hardwarelogfail Enables/disables alert generation when a hardware log
detects a failure value.
event=intrusion Sets action or enables/disables alert generation when a
chassis is opened.
Table 4-25. Parameters for Alert Action Command (continued)
Action Description