User's Manual
136 omconfig: Managing Components Using the Instrumentation Service
omconfig system platformevents/omconfig servermodule platformevents
Use the omconfig system platformevents or omconfig servermodule
platformevents command to configure shutdown action, if any, to be taken for a
specific platform event. You can also enable or disable platform event filter
alert generation.
CAUTION: If you set a platform event shutdown action to anything other than
"none" or "power reduction", your system will forcefully shutdown when the
specified event occurs. This shutdown is initiated by firmware and is carried out
without first shutting down the operating system or any of the applications running
on your system.
Table 4-25 shows the valid parameters for the command.
NOTE: Alert settings are mutually exclusive and can be set one at a time only.
The action settings are also mutually exclusive and can be set one at a time only.
However, alert and action settings are not mutually exclusive of each other.
Table 4-24. omconfig system pedestinations/omconfig servermodule pedestinations
name=Value Pair Description
destenable=true |
false
true: Enables an individual platform event filter destination
after a valid IP address has been set.
false: Disables an individual platform event filter.
index=number Sets the index for the destination.
ipaddress=ipv4|ipv6
address
Sets the IP address for the destination.
communitystr=text Sets the text string that acts as a password and is used to
authenticate SNMP messages sent between the BMC and the
destination management station.
Table 4-25. Parameters for Alert Action Command
Action Description
alert=disable Disables the SNMP alert.
alert=enable Enables the SNMP alert to be sent.
action=none Takes no action when the system is hung or has crashed.
action=powercycle Turns off the electrical power to the system, pauses, turns the
power on, and reboots the system.
action=poweroff Turns off the electrical power to the system.