User's Manual

omconfig: Managing Components Using the Instrumentation Service 133
NOTE: storagectrlbatterywarn and storagectrlbatteryfail events are not available
on modular systems.
Example Set Alert Action Commands
The examples below are valid example commands. For each successful
command issued, the following message appears:
Alert action(s) configured successfully.
event=tempwarn Sets actions when a temperature probe detects a warning
value.
event=tempfail Sets actions when a temperature probe detects a failure
value.
event=voltwarn Sets actions when a voltage probe detects a warning value.
event=voltfail Sets actions when a voltage probe detects a failure value.
event=watchdogasr Sets actions that Server Administrator performs on the
next system startup after a watchdog Automatic System
Recovery (ASR) is performed for a hung operating system.
event=storagesyswarn Sets actions when a storage system detects a warning
value.
event=storagesysfail Sets actions when a storage system detects a failure value.
event=storagectrlwarn Sets actions when a storage controller detects a warning
value.
event=storagectrlfail Sets actions when a storage controller detects a failure
value.
event=pdiskwarn Sets actions when a physical disk detects a warning value.
event=pdiskfail Sets actions when a physical disk detects a failure value.
event=vdiskwarn Sets actions when a virtual disk detects a warning value.
event=vdiskfail Sets actions when a virtual disk detects a failure value.
event=enclosurewarn Sets actions when an enclosure detects a warning value.
event=enclosurefail Sets actions when an enclosure detects a failure value.
event=
storagectrlbatterywarn
Sets actions when a storage controller battery detects a
warning value.
event=
storagectrlbatteryfail
Sets actions when a storage controller battery detects a
failure value.
Table 4-23. Events for Which You Can Set Alert Actions (continued)
Event Name Description