SNMP Reference Guide
Table Of Contents
- Introduction
- Audience
- What’s New in this Release
- Introduction to the SNMP Reference Guide
- General Content
- Server Administrator Instrumentation MIB
- Server Administrator Remote Access MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Storage Management MIB
- Server Administrator Change Management MIB
- Dell RAC Out-of-Band MIB
- How This Guide Defines Technical Terms
- SNMP Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Reference Guide Content Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- Instrumentation MIB Version Group
- Systems Management Software Group
- Systems Management Software
- Systems Management Software Name
- Systems Management Software Version Number Name
- Systems Management Software Build Number
- Systems Management Software Description Name
- Systems Management Software Supported Protocol
- Systems Management Software Preferred Protocol
- Systems Management Software Update Level Name
- Systems Management Software URL Name
- Systems Management Software Language Name
- Systems Management Software Global Version Name
- Systems Management Software Feature Flags
- Systems Management Software SNMP Agent Feature Flags
- Systems Management Software Manufacturer Name
- Systems Management Software Variable Values
- Systems Management Software
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- User Security Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Remote Access Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- Dell RAC Out-of-Band Group
- Product Information
- Chassis Status
- DRsGlobalSystemStatus
- DRsGlobalCurrStatus
- DRsIOMCurrStatus
- DRsKVMCurrStatus
- DRsRedCurrStatus
- DRsPowerCurrStatus
- DRsFanCurrStatus
- DRsBladeCurrStatus
- DRsTempCurrStatus
- DRsCMCCurrStatus
- DRsGlobalPrevStatus
- DRsIOMPrevStatus
- DRsKVMPrevStatus
- DRsRedPrevStatus
- DRsPowerPrevStatus
- DRsFanPrevStatus
- DRsBladePrevStatus
- DRsTempPrevStatus
- DRsCMCPrevStatus
- DRsIOMChangeTime
- DRsKVMChangeTime
- DRsRedChangeTime
- DRsPowerChangeTime
- DRsFanChangeTime
- DRsBladeChangeTime
- DRsTempChangeTime
- DRsCMCChangeTime
- Chassis Power
- CMC Power Information
- CMC PSU Information
- Chassis Alerts
- Legacy Alerting
- Traps
- Trap Variables
- Understanding the Trap Description
- Understanding Trap Severity
- Instrumentation Traps
- Miscellaneous Traps
- Temperature Probe Traps
- Cooling Device Traps
- Voltage Probe Traps
- Amperage Probe Traps
- Chassis Intrusion Traps
- Redundancy Unit Traps
- Power Supply Traps
- Memory Device Traps
- Fan Enclosure Traps
- AC Power Cord Traps
- Hardware Log Traps
- Processor Device Status Traps
- Pluggable Device Traps
- Battery Traps
- RAC Traps
- BMC Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
- Glossary
- Index

Remote Flash BIOS Group 211
Remote Flash BIOS Status
Remote Flash BIOS Last BIOS Date Name
Remote Flash BIOS Completion Code
Remote Flash BIOS Minimum Contiguous Memory
Name remoteFlashBIOSStatus
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.5
Description Defines the status of the remote BIOS update hardware on
this system.
Syntax DellRemoteFlashBIOSStateStatus
Access Read-only
Name remoteFlashBIOSLastBIOSDateName
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.6
Description Defines the date of the last BIOS update.
Syntax DellDateName
Access Read-only
Name remoteFlashBIOSCompletionCode
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.7
Description Defines the completion code of the last BIOS update.
Syntax DellRemoteFlashBIOSCompletionCode (See Table 11-3.)
Access Read-only
Name remoteFlashBIOSMinimumContiguousMemory
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.8
Description Defines the minimum size of contiguous memory required for
remote BIOS update in kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only